Independent homeowner planningSources shown. Assumptions visible.

Open planning model · version 1.0

See exactly how our HVAC calculators reach a result

This is the working model behind the site’s three planning tools. It publishes the starting bands, multipliers, adders, scoring rules, rounding, limitations, and worked examples so a reader can reproduce a result without trusting a hidden formula.

Version1.0
Last checkedAugust 31, 2026
GeographyU.S. planning ranges
PrecisionNearest $500

Purpose and limits

A decision screen, not a price oracle

Residential HVAC prices are not published in one complete national database. A contractor’s total combines equipment, local labor, company overhead, permit and inspection requirements, design work, access, electrical or fuel work, ducts, controls, commissioning, warranty obligations, and risk. A precise browser result would hide that uncertainty instead of helping a homeowner manage it.

The model therefore begins with broad editorial bands for recognizable project configurations and adjusts them only for variables the user can describe before an on-site visit. The ranges are intentionally wide. They are useful for building a contingency, spotting missing scope, and asking why local proposals differ. They are not evidence that a local contractor is overcharging or undercharging.

Capacity screens are also deliberately rough. Square footage cannot replace a Manual J calculation because climate, orientation, insulation, air leakage, windows, internal loads, ventilation, ducts, and design temperatures change the load. The model shows when a proposal deserves a documented sizing explanation; it does not select equipment.

Model 01

Whole-system replacement cost

Base band × size factor × efficiency factor × labor factor + duct allowance.

Starting installed-cost bands used by the live calculator
ConfigurationLowHighScope represented
Central AC + gas furnace$8,500$15,500Matched outdoor AC, indoor coil, and gas furnace.
Ducted heat pump$9,500$18,000All-electric heating and cooling with standard air handler.
Dual-fuel heat pump$12,000$23,000Heat pump paired with a gas furnace for backup heat.
Packaged HVAC system$8,000$15,000Single outdoor cabinet; common in some warmer regions.

Size factor

The model uses 0.75 + square feet ÷ 7,200, capped between 0.86 and 1.32. This is a cost adjustment—not a load calculation. It allows a 3,500-square-foot project to carry more equipment and labor allowance than an 800-square-foot project without claiming that floor area determines tons.

Efficiency and market

Entry equipment uses 1.00, enhanced efficiency 1.12, and premium or variable-speed equipment 1.25. Labor-market factors are 0.90, 1.00, and 1.18. These factors widen a planning scenario; they do not quote a specific brand or ZIP code.

Duct allowance

Keeping tested ducts adds $0. Sealing or sectional repair adds $1,500–$4,500; substantial replacement adds $4,500–$12,000. Access, materials, fire or smoke requirements, and redesign can move real work outside the allowance.

Model 02

Mini-split project cost

First-zone band + added zones, then area and equipment factors, access, and electrical work.

Indoor-unit configuration bands
Indoor-unit styleFirst zoneEach added zone
Wall-mounted heads$4,000$7,500$2,500$4,500
Mix of wall and compact heads$5,000$8,500$3,000$5,200
Ceiling cassettes / concealed ducts$6,000$10,500$3,500$6,000

Area and equipment

The area factor starts at 0.90 and increases after 600 square feet, capped at 1.28. Standard equipment uses 1.00, enhanced 1.12, and cold-climate or premium equipment 1.22. Area is a cost signal only; the capacity screen remains a broad 18–30 BTU/h per square foot to make its uncertainty visible.

Access

Simple accessible runs add $0; mixed access or longer runs add $1,000–$3,000; difficult access or finish repair adds $3,000–$8,000. The quote should state line length, routing, condensate, lifting, penetrations, and finish responsibility.

Electrical

A suitable existing circuit adds $0. A new circuit and disconnect add $500–$1,800; possible panel or service work adds $2,000–$5,500. A licensed electrician must confirm capacity and code requirements.

Model 03

Repair-or-replace signal

A disclosed score organizes evidence; it does not predict failure or remaining life.

Factors that move the decision signal
FactorMaximum weightWhy it matters
Age3 pointsOlder equipment raises the relevance of another near-term major failure, but age alone never forces replacement.
Repair share3 pointsThe quote is divided by the midpoint of a broad replacement band for the selected system.
Other repairs2 pointsRepeated repairs weaken the assumption that today’s repair ends the spending cycle.
Comfort and reliability2 pointsUneven conditions or repeated shutdowns may indicate a design or system problem beyond one part.
Energy-use pattern1.5 pointsA sharp unexplained change deserves diagnosis; weather-normalized utility data is stronger than one bill.
Warranty status0.5 pointSubstantial coverage can change the household cost even when the technical repair is the same.

0–3: repair first

The inputs do not show a strong replacement signal. Confirm diagnosis, coverage, and the repair guarantee before authorizing work.

More than 3–6: compare

The tradeoff is close enough to justify a second diagnosis and comparable replacement scopes, including defects each proposal corrects.

More than 6–10: replacement case

Several inputs reduce the value of a major repair. Replacement still needs correct design, total financing cost, and a defined commissioning plan.

The calculator uses replacement bands of Central AC + furnace $8,500–$15,500; Ducted heat pump $9,500–$18,000; Furnace only $4,500–$9,500; Single-zone mini-split $4,000–$7,500. Safety findings override the score. A cracked heat exchanger, combustion concern, electrical hazard, or refrigerant exposure belongs with qualified professionals and applicable emergency guidance—not a cost formula.

Evidence standard

What comes from sources—and what remains editorial

Technical and program claims are checked first against government agencies, recognized standards organizations, official program administrators, utilities, and manufacturer documentation. Examples include federal efficiency terminology, tax instructions, refrigerant rules, equipment performance data, and the role of Manual J, Manual S, and quality installation practices.

The dollar bands and adjustment factors on this page are editorial planning assumptions. They are not government statistics, scraped contractor bids, or a proprietary real-time price feed. Publishing them here makes that distinction auditable. We change them only as a versioned model release, then check that the same constants power the live tools and worked examples.

Before publication, we test calculator boundaries, reproduce the examples, check that low results remain below high results, review safety wording, and verify every linked source is relevant to the claim around it. We do not invent professional review, field tests, contractor interviews, owner experience, or local prices.

Change log

Model releases

Version 1.0 — public model release

Published all base bands, multipliers, adders, scoring rules, formulas, and two reproducible cost examples. Centralized the model constants so this research page and the live calculators use the same values. Added a downloadable CSV for offline quote planning.